13 Panel FYL Urine Test with ADLTX
You save
As low as 4.09 CHF
VAT (25%) is included in the price
| SERENITY MULTI DRUG DOA CUP: 13 Panel Drug Test Cup |
| FEN/20, AMP/1000, BAR/300, BUP/10, BZO/300, COC/300, MDMA/500, MET/1000, MTD/300, OPI/300, OXY/100, TCA/1000, THC/50 |
& 3 adulterations Specific Gravity, pH, and Creatinine
13 Panel Drug Screen with Fentanyl and ADLTX
The need to reduce falsification in drug testing led to the creation of this unique 13-panel drug test.
Key features:
- cost-effective – best market price
- easy-to-read peel-off label
- rounded design
- leak-proof, drip-free screw cap
- built-in temperature strips
- built-in three adulteration checks
- 99.99% accuracy rating
In addition to screening for the 13 most common drugs, it features extra adulteration strips that can detect any tampering with the urine sample.
Adulteration parameters (creatinine, specific gravity, and pH) are important because they help identify any manipulation of the urine sample.
What is included in a 13 Panel Urine Drug Test:
| Drug / Substance | Cut-off Level | Detection Time |
| Amphetamines/AMP | 1000 ng/mL | 1-2 days |
| Barbiturates/BAR | 300 ng/mL | 1-4 days |
| Benzodiazepines/BZO | 300 ng/mL | 1-2 days |
| Buprenorphine/BUP | 10 ng/mL | 2-6 days |
| Cocaine/COC | 300 ng/mL | 2-4 days |
| Ecstasy/MDMA | 500 ng/mL | 2-4 days |
| Fentanyl/FYL | 20 ng/mL | 2-3 days |
| Marijuana/THC | 50 ng/mL | 5+ days |
| Methadone/MTD | 300 ng/mL | 1-3 days |
| Methamphetamine/mAMP (or MET) | 1000 ng/mL | 2-4 days |
| Morphine/OPI | 300 ng/mL | 2-3 days |
| Oxycodone/OXY | 100 ng/mL | 1-3 days |
| Phencyclidine/PCP | 25 ng/mL | 7-14 days |
& 3 adulterationen Spezifisches Gewicht, pH, and Kreatinin
Adulteration Test
The adulteration test using these strips is a procedure that checks for any kind of manipulation of the donor’s urine sample.
These additional ADLTX strips further reduce the already minimal chance that the sample was altered or manipulated before testing.
Some of the most commonly used adulterants in urine drug tests are:
- table salt
- household vinegar
- liquid laundry detergent (bleach)
- lemon juice
- diluted urine (creatinine < 15 mg/mL)
- Visine eye drops
Drug test cups with adulteration test are designed to be user-friendly and highly reliable.
Reading the Adulteration Test

13 Panel Drug Screen Instructions
Be sure to follow these few simple steps when using the 13 panel cup.
- Open:
The drug testing device should be held at temperatures between 2–26 °C (36–78 °F). If this is followed, the cup can be removed from the packaging slowly. - Collect:
Urine should be administered into the open cup only once you are ready to use the device; otherwise, it should remain closed. - Check:
Once the urine is in, the temperature strips on the cup should show a temperature of between 32–38 °C (90–100 °F). - Wait:
Once the urine has been administered and the cup closed, wait for 5 minutes at least. If you check the test sooner than that, the results will be inconclusive. - Peel:
Once the 5 minutes have passed, you can read the results of the test by looking at the test strips membrane which is printed out on the cup itself. - Read:
Following the instructions on how to read the test, take a look at the membranes of the strips. Keep a close eye on the C and T markings.
How to Use the 13 Panel Cup
How to Read a 13 Panel Drug Test Cup with ADLTX
To read the 13 panel drug test cup with ADLTX, simply follow the instructions on the page or on your cup. All test strips in the cup can be read by looking at the red lines that appear.
The 13 panel drug test cup is a highly sensitive screening that complies with SAMHSA cutoff levels.
With the addition of adulteration checks (ADLTX), accuracy is significantly increased because the risk of testing manipulated samples is minimal.
It is recommended to wait at least 5 minutes after performing the test to ensure the cup delivers a clear and readable result.
Positive
Only one colored band appears in the control region (C). No visible colored band appears in the test region (T).
Negative
Two colored bands appear on the membrane. One band appears in the control region (C), and another band appears in the test region (T).
Invalid
The control band fails to appear. Results from any test which has not produced a control band at the specified read time must be discarded.
You must be logged in to post a review.
Related products
16 panel drug test cup with FYL, TRA, and EtG
You save
As low as 5.39 EUR
VAT (25%) is included in the price| SERENITY MULTI DRUG DOA CUP: 16 Panel Drug Test Cup |
| TRA/100, FEN/20, ETG/300, AMP/1000, BAR/300, BUP/10, BZO/300, COC/300, MDMA/500, MET/1000, MTD/300, OPI/300, OXY/100, PCP/25, TCA/1000, THC/50 |
8 Panel Drug Test – Rapid Drug Screening Test Cup
You save
As low as 4.19 EUR
VAT (25%) is included in the price| SERENITY MULTI DRUG DOA CUP: 8 Panel Drug Test Cup |
| AMP/1000, BUP/10, BZO/300, COC/300, MET/1000, OPI/300, OXY/100, THC/50 |
10 Panel Urine Drug Test with FYL
You save
As low as 4.29 EUR
VAT (25%) is included in the price| SERENITY MULTI DRUG DOA CUP: 10 Panel Drug Test Cup |
| FEN 20, AMP/1000, BUP/10, BZO/300, COC/300, MET/1000, MTD/300, OPI/300, OXY/100, THC/50 |
14 Panel Drug Test Cup with EtG & PCP
You save
As low as 4.89 EUR
VAT (25%) is included in the price| SERENITY MULTI DRUG DOA CUP: 14 Panel Drug Test Cup, |
| PCP/25, ETG/300, FEN/20, AMP/1000, BAR/300, BUP/10, BZO/300, COC/300, OPI/300, MDMA/500, MET/1000, MTD /300, OXY/100, THC/50 |

Reviews
There are no reviews yet.